What If? Lab

What if a house were built on soft clay?

Every building stands on the ground. Some ground is firm, and some is soft. What if we built on soft clay? Let's try it in Olly's lab!

A building presses down on the ground under its foundation. Sand, gravel and rock can each safely carry a different amount. In this lab, a 300-tonne building stands safely on sand. Move it onto soft clay without changing anything else, and see what happens and how to fix it.

Bearing pressure is weight ÷ footing area, and each ground type has an allowable pressure. Using the presumptive values in a residential building code, move a 300 t building on a 40 m² footing from sand (95.8 kPa allowed) to clay or silt (71.8 kPa), then find the footing area clay needs and compare with real code footing widths.

Explore

The big question

A house sits on its foundation. The foundation sits on the ground.

Some ground is firm, like rock. Some is soft, like clay. What if a house were built on soft clay?

Under every building is a foundation, the part that carries the building's weight down into the ground. The bottom of it, which spreads the weight out, is called a footing.

But the ground isn't all the same. Solid rock can carry a lot. Sand and gravel can carry less, and soft clay and silt less again. What happens if the same building, on the same footing, is moved from sand onto soft clay?

A shallow foundation transfers a building's weight to the soil through a footing, producing a bearing pressure q = m·g ÷ A. Building codes give presumptive allowable pressures for each class of ground, to be used where no full geotechnical evaluation is done.

This lab uses those presumptive values to ask what happens when a 300 t building on a 40 m² footing is moved from sand to clay or silt, and how large the footing must become to bring the pressure back within the allowable value.

Try the experiment

Make a prediction

The building is safe on sand. Olly moves it onto soft clay. What will happen?

The 300-tonne building is safe on sand, using 77% of the safe limit. If the same building on the same footing stands on clay instead, what does the model say?

A 300 t building on a 40 m² footing is moved from sand (95.8 kPa allowed) to clay or silt (71.8 kPa). What is the verdict?

  • It is a little too much: the ground squashes
  • It is even safer
  • Nothing changes
What you can change
ControlIn our worldWhat if…Range
Ground · What the footing rests on. Try sand, then clay or silt. 1 0 0–4
Footing size · How much ground the footing presses on. A bigger footing spreads the weight out. 40 m² — 2–500 m²
Building mass · How heavy the whole building is, in tonnes. 300 t — 10–5000 t
  • Established fact

    Pressure is a push spread over an area. A bigger area means less pressure.

    Pressure is force divided by area, so the same weight on a bigger footing presses more gently on the ground.

    Pressure P = F ÷ A (OpenStax); a footing lowers bearing pressure by spreading the building's weight over a larger area.

  • Established fact

    Building rules say clay can carry less than sand, gravel or rock.

    A building code's table gives clay and silt the lowest safe value: 1,500 pounds per square foot, against 2,000 for sand and 12,000 for solid bedrock.

    Presumptive load-bearing values (Residential Code of Ohio Table 401.4.1): clay and silt 1,500 psf, sand 2,000, gravel 3,000, sedimentary rock 4,000, crystalline bedrock 12,000.

  • What the model shows

    In the model, the same building is safe on sand but sinks on clay.

    In the model, the 300-tonne building on 40 square meters uses 77% of the safe limit on sand but 102% on clay, so the model says it would sink.

    q = 73.6 kPa: 77% of 95.8 kPa on sand (safe), 102% of 71.8 kPa on clay (settles); the minimum safe footing rises from 30.7 m² to 41.0 m².

  • Established fact

    Real houses on clay get wider footings.

    For a two-story house with a basement, the Ohio code asks for a 22-inch-wide footing on clay but only 16 inches on sand.

    Table 403.1(1) (20 psf snow load, two-story with basement): 22 in on 1,500 psf soil, 16 in on 2,000 psf, 12 in on 3,000 psf.

  • What the model shows

    The model's sinking picture shows the idea; it doesn't measure the sinking.

    The model uses one safe value for each kind of ground and doesn't work out how far a building would sink. Real sites need soil tests.

    The model uses presumptive values with a rough three-band verdict; it does not compute settlement, layering, water or deep foundations, and the code calls for a soils investigation where weaker ground is likely.

On sand

Olly's building stands on sand. Its big, flat foot spreads out its weight.

The sand can hold it. The building is safe.

In the model, a 300-tonne building rests on a footing that covers 40 square meters of sandy ground. Its weight presses on the sand with a pressure of about 74 kilopascals (the readout shows 73.6).

The model's safe limit for sand is about 96 kilopascals, so the building uses 77% of it. Safe! In fact, the model says any footing bigger than about 31 square meters would be safe on this sand.

The bearing pressure is 300,000 kg × 9.81 m/s² ÷ 40 m² = 73.6 kPa. For sand, silty sand and clayey sand, the code's presumptive value is 2,000 psf, or 95.8 kPa, so the footing uses 77% of the allowable pressure and the verdict is safe.

The smallest safe footing on sand is A_min = m·g ÷ q_allowable = 30.7 m².

On soft clay

Now Olly moves the same building onto soft clay.

Clay can't hold as much. The building is now a little too heavy for it, so it sinks!

Now switch the ground to clay or silt. The building and its footing are exactly the same, so the pressure is still 73.6 kilopascals. But the model's safe limit for clay is only about 72 kilopascals.

The building now uses 102% of the safe limit. That's just over, but the model says the ground would squash, so the building would sink and might crack or tilt. Make the footing a little bigger, 42 square meters, and it's safe again. Shrink it to 13 square meters, and the model says the clay would give way.

On clay or silt, with a presumptive value of 1,500 psf (71.8 kPa), the same 73.6 kPa uses 102% of the allowable pressure; the model's rough rule classes 100–300% as settlement (sinking, cracking or tilting) and more than 300% as bearing failure.

The smallest safe footing on clay is 41.0 m², a third larger than the 30.7 m² sand needs, because 2,000 ÷ 1,500 = 1.33. At 42 m² the use drops to 98%; at 30 m² it is 137%; at 13 m² it reaches 315% and the model predicts the soil gives way.

Why soft ground needs a bigger foot

Pressure is how hard something pushes on each bit of ground.

A bigger foot spreads the push out. Then each bit of ground gets a gentler push.

Pressure is the force divided by the area it's spread over. The building's weight doesn't change, but spreading it over a bigger footing lowers the pressure on every square meter of ground.

Soft clay can only take a gentle press before it starts to squash. So a building on clay needs a wider footing than the same building on sand, gravel or rock.

Since q = F ÷ A, the footing area needed scales inversely with the allowable pressure: A_min = m·g ÷ q_allowable. With presumptive values of 1,500, 2,000, 3,000, 4,000 and 12,000 psf, a 300 t building needs 41.0, 30.7, 20.5, 15.4 and 5.12 m² of footing on clay, sand, gravel, sedimentary rock and crystalline bedrock.

The model's limits: an even pressure under a shallow footing, one presumptive value per ground class, and a rough three-band verdict. It does not calculate how far a building sinks, how soil changes with depth and water, or deep foundations such as piles. The code itself requires a soils investigation where ground weaker than 1,500 psf is likely.

Real footings and a famous tower

Builders make footings wider on soft ground.

A famous tower in Italy leans because its ground is soft!

Building rules really do ask for wider footings on softer ground. In the Residential Code of Ohio, a two-story house with a basement needs a footing 22 inches (about 56 centimeters) wide on clay or silt, but only 16 inches (about 41 centimeters) on sand and 12 inches (about 30 centimeters) on gravel, in the table for the lightest snow loads.

The Leaning Tower of Pisa in Italy shows what can happen when ground settles unevenly. Building began in 1173. Britannica explains that after three of its eight stories were built, its foundations had already begun settling unevenly in the soft ground.

Table 403.1(1) of the Residential Code of Ohio, based on the International Residential Code, sets minimum footing widths by soil load-bearing value. For a two-story light-frame house with a basement and a 20 psf snow load, it requires 22 inches on 1,500 psf soil, 16 inches on 2,000 psf and 12 inches on 3,000 psf. Where compressible or shifting soils are present, section 401.4.3 requires them to be removed or stabilized.

Britannica attributes the lean of the Leaning Tower of Pisa, begun in 1173, to uneven settling of its foundations in soft ground. A stabilization project began in 1990: earth was removed from beneath the foundations, and by 2001 the lean had been reduced.

Amazing facts

  • Solid bedrock can hold eight times as much as clay.

    In the building code's table, crystalline bedrock can safely carry 12,000 pounds per square foot: eight times the 1,500 allowed for clay.

    Presumptive values range from 1,500 psf for clay and silt to 12,000 psf for crystalline bedrock, a factor of eight (Residential Code of Ohio Table 401.4.1).

  • Pisa's tower stopped being built for a long time.

    The Leaning Tower of Pisa took a long break from building: work stopped for almost a century after its first three stories.

    Britannica notes that construction at Pisa was halted for almost a century after the third story, a pause that let the foundation settle and likely prevented an early collapse.

  • Builders sometimes dig soft soil out and take it away.

    Where the soil near the top is soft and squashy, a building code can require it to be dug out or made firmer before building.

    Section 401.4.3 of the Ohio residential code requires compressible or shifting top soils or subsoils to be removed, or stabilized, unless a full geotechnical evaluation is done.

Words to know

foundation
the part of a building that carries its weight down into the ground
footing
the wide base of a foundation that spreads the weight over the ground
pressure
how hard something pushes on each bit of area: force divided by area
clay
a fine, sticky soil that can squash under heavy loads
bedrock
the solid rock beneath the soil
settle
to sink slowly into the ground under a building's weight

Discovery challenge

  1. Which ground can hold the most weight?

    Which kind of ground can safely carry the most pressure?

    Which class of material has the highest presumptive load-bearing value?

    • Solid bedrock
    • Sand
    • Soft clay
    Show the answer

    Solid bedrock

    Solid rock is the strongest.

    Crystalline bedrock: 12,000 pounds per square foot in the code's table.

    Crystalline bedrock, 12,000 psf (574.6 kPa).

  2. In the model, what happens when the building moves from sand to clay?

    In the model, what happens to the 300-tonne building when it moves from sand to clay?

    What verdict does the model give for 300 t on 40 m² of clay or silt?

    • It is just too much, so it sinks
    • It becomes even safer
    • Nothing changes
    Show the answer

    It is just too much, so it sinks

    It is a little too heavy for the clay, so it sinks.

    It uses 102% of clay's safe limit, so the model says it would sink and might crack or tilt.

    Settles: 73.6 kPa is 102% of clay's 71.8 kPa.

  3. How can Olly make the building safe on clay?

    How can the building be made safe on clay without making it lighter?

    Holding the mass fixed, which change restores a safe verdict on clay?

    • Make the footing bigger
    • Make the footing smaller
    • Paint the building
    Show the answer

    Make the footing bigger

    A bigger foot spreads the weight.

    Make the footing bigger: 42 square meters brings it to 98% of the limit.

    Increase A to at least 41.0 m², since q = m·g ÷ A.

  4. Why does the famous tower in Pisa lean?

    Why does the Leaning Tower of Pisa lean?

    Britannica attributes the Pisa tower's lean to…

    • Its ground is soft, so it sank unevenly
    • It was built leaning on purpose
    • Strong winds pushed it
    Show the answer

    Its ground is soft, so it sank unevenly

    Its foundation sank more on one side in the soft ground.

    Its foundations settled unevenly in the soft ground.

    …uneven settling of its foundations in soft ground.

Experiments to try

Explore next

For parents & teachers

What children will learn

  • A foundation spreads a building's weight over the ground; pressure is force divided by area.
  • Different ground can safely carry different pressures, with soft clay and silt among the lowest.
  • Buildings on softer ground need wider footings, as building codes require.
  • Simple models leave out soil layers, water and how far a building actually sinks.

Recommended ages: 9 to 17 · About 15 minutes

Talk about it

  • Why might wide shoes or boards help people walk on soft mud or deep snow, and how is that like a footing?
  • What could happen to a house if one side of its foundation sank more than the other?
  • Why might builders test the soil before they start?

Try at home or in class

  • Fill one tray with damp sand and another with soft modeling clay or wet mud. Press a small stack of books on a bottle cap into each, then on a jar lid. Which sinks most, and which lid size helps?
  • Press your fingertip and then your whole palm gently into a lump of dough. Compare the dents.

Key vocabulary: foundation, footing, pressure, clay, bedrock, settle

Where these facts come from

  1. Residential Code of Ohio, rule 4101:8-4-01 Foundations, Table 401.4.1 Presumptive Load-Bearing Values of Foundation Materials , State of Ohio, Board of Building Standards
  2. College Physics 2e, §11.3 Pressure , OpenStax
  3. Leaning Tower of Pisa , Encyclopaedia Britannica

Checked, not yet human-reviewed. Last updated October 26, 2026. Spotted a mistake? Tell us.